Stainless Steel Tube Pressure Rating Charts | Titan Fittings
Tube
OD in. |
Tube Wall Thickness, in. |
Swagelok
Fitting Series |
|||||||||
0.028 | 0.030 | 0.035 | 0.049 | 0.065 | 0.083 | 0.095 | 0.109 | 0.120 | 0.134 | ||
Working Pressure, psig Note: For gas service, select a tube wall thickness outside of the shaded area. (See Gas Service, page 22.) |
|||||||||||
1/8 | 2700 | 3000 | 3600 | 200 | |||||||
3/16 | 1800 | 1900 | 2300 | 3400 | 300 | ||||||
1/4 | 1300 | 1400 | 1600 | 2500 | 3500 | 400 | |||||
5/16 | 1300 | 1900 | 2700 | 500 | |||||||
3/8 | 1000 | 1600 | 2200 | 600 | |||||||
1/2 | 800 | 1100 | 1600 | 2100 | 810 | ||||||
5/8 | 900 | 1200 | 1600 | 1900 | 1010 | ||||||
3/4 | 700 | 1000 | 1300 | 1500 | 1800 | 1210 | |||||
7/8 | 600 | 800 | 1100 | 1300 | 1500 | 1410 | |||||
1 | 500 | 700 | 900 | 1100 | 1300 | 1500 | 1610 | ||||
1 1/8 | 600 | 800 | 1000 | 1100 | 1300 | 1400 | 1810 |
Tube
OD in. |
Tube Wall Thickness, in. |
Swagelok
Fitting Series |
|||||||||||||||
0.010 | 0.012 | 0.014 | 0.016 | 0.020 | 0.028 | 0.030 | 0.035 | 0.049 | 0.065 | 0.083 | 0.095 | 0.109 | 0.120 | 0.134 | |||
Burst Pressure, psig Note: For gas service, select a tube wall thickness outside of the shaded area. (See Gas Service, page 22.) |
|||||||||||||||||
1/16 | 5600 | 6800 | 8100 | 9400 | 12000 | 400 | |||||||||||
1/8 | 10800 | 12000 | 14400 | 800 | |||||||||||||
3/16 | 5400 | 7600 | 9200 | 13600 | 1200 | ||||||||||||
1/4 | 5200 | 5600 | 6400 | 10000 | 14000 | 1600 | |||||||||||
5/16 | 5200 | 7600 | 10800 | 2000 | |||||||||||||
3/8 | 4000 | 6400 | 8800 | 2400 | |||||||||||||
1/2 | 3200 | 4400 | 6400 | 8400 | 3240 | ||||||||||||
5/8 | 3600 | 4800 | 6400 | 7600 | 4040 | ||||||||||||
3/4 | 2800 | 4000 | 5200 | 6000 | 7200 | 4840 | |||||||||||
7/8 | 2400 | 3200 | 4400 | 5200 | 6000 | 5640 | |||||||||||
1 | 2000 | 2800 | 3600 | 4400 | 5200 | 6000 | 6440 | ||||||||||
1 1/8 | 2400 | 3200 | 4000 | 4400 | 5200 | 5600 | 8000 | ||||||||||
1 - For higher pressures, see please contact Titan Fittings.
2 - Rating based on repeated pressure testing with a 4:1 design factor based upon hydraulic fluid leakage.